No.7 Sheng Feng Road, Xin He Industril Zone, Dong Guan City, Guang Dong Province, China
Home ProductsUN38.3 Battery testing equipment

RT + 10~100℃ Battery External Short Circuit Test Chamber PLC / Remote Control upto 1000A ( UN38.3.4.5)

RT + 10~100℃ Battery External Short Circuit Test Chamber PLC / Remote Control upto 1000A ( UN38.3.4.5)

RT + 10~100℃ Battery External Short Circuit Test Chamber PLC / Remote Control upto 1000A ( UN38.3.4.5)

Product Details:

Place of Origin: China
Brand Name: Gaoxin
Certification: ISO
Model Number: GX-6055 NT

Payment & Shipping Terms:

Minimum Order Quantity: 1set
Price: negotiation
Packaging Details: Non-fumigation wooden box
Delivery Time: 25 working days
Payment Terms: FOB Shenzhen, L/C, T/T, Western Union
Supply Ability: 50 sets per month
Contact Now
Detailed Product Description
Control System: PLC Touch Interface PID Temperature Control: Automatic Constant Temperature And High Temperature Compensation
Data Recorder: Record Battery Surface Temperature, Current, And Voltage Max. Circuit Current: 1000A
Remote Control Distance: No Solid Barrier 7 Meters Internal Resistance Of Device: 80±20mΩ
Current, Voltage, Temperature Acquisition Channels: Total 8 Channels Max. Measurable Battery Voltage: 100V

Product name: Battery Short Circuit Testing Equipment


Model number: GX-6055-NT

 

Test procedure:

 

The Cell or battery to be tested shall be heated for a period of time necessary to reach a homogeneous stabilized temperature of 57 ± 4 ℃, measured on the external case, this period of time depends on the size and design of cell or battery and should be assessed and documented, if this assessment is not feasible, the exposure time shall be at least 6 hours for small cells and small batteries, and 12 hours for large cells and large batteries, then the cell or battery at 57 ± 4 ℃ shall be subjected to one short circuit condition with a total external resistance of less than 0.1ohm.

 

This Short circuit condition is continued for at least one hour after the cell or battery external  case temperature has returned to 57 ± 4 ℃, or in the case of large batteries, has decreased by half of the max. temperature increase observed during the test and remains below that value.

 

The short circuit and cooling down phases shall be conducted at least at ambient temperature.

 

Requirement

 

Cells and batteries meet this requirement if their external temperature does not exceed 170℃ and there is no disassembly, no rupture and no fire during the test and within siz hours after the test


Equipment description

 

1.1 The remote controlled high current short circuit test machine is designed to meet the various battery short-circuit test requirements. The short circuit test machine must meet the internal resistance range according to the standard requirements. ≤100mΩ to obtain the maximum short-circuit current required by the test.


1.2 Control mode: PLC control, use Schneider AC contactor as switch component, set test conditions on PLC interface, contactor suck and send strong short-circuit current to make the whole circuit short, reach the test required current, The loop resistance in the process of the equipment (ie contactor resistance + connection terminal + battery fixture total resistance of 80 ± 20mΩ). The maximum short-circuit current from the contactor is 1000A. The maximum short-circuit current that the test circuit can withstand is 1000A. The battery surface temperature, voltage change data, and current change data during the test are detected by the acquisition element and fed back to the PLC main control program.

 

Standard Basis:

 

UN38.3, IEC62133, IEC 62281, IEC 60086, UL 1642, UL 2054....

 

Working voltage AC 220V 50Hz-60Hz
Impact voltage AC 1kv/1.2-50μs <peak value> 1min
Operation characteristics

Cold state pull-in voltage ≯66%Us

Cold state releasing voltage ≯30%Us,≮5%Us
Short circuit mode Pneumatic suction
Maximum measurable battery voltage 100V
HVDC response time ≤5μs
Max. circuit current 1000A
Short circuit resistance 80 ± 20mΩ
Remote control distance 7 meter
Test temperature range RT+10~100℃
Current, voltage, temperature acquisition channels Total 8 channels
Actuation time Response time / releasing time ≯30ms
Mechanical life 300,000 times
Temperature control accuracy 0.1℃
Temperature uniformity ±2℃
Temperature fluctuation ±0.5℃
Interior test chamber size 400*400*400mm
External test chamber size 950*850*1650mm
Working environment Temperature: -10℃~100℃ humidity: 10~90%
Supply power AC220V , 50HZ
Equipment power

2.5KW

 

Feature:

 

Control system

1. PLC touch interface.

2. PID temperature control, automatic constant temperature and high temperature compensation.

3. Record battery surface temperature, current, and voltage.

4. The test process is automatically controlled.
High current contactor

1. The rated working current is 1000A DC, equipped with a series magnetic blower vertical partition clay extinguishing arc extinguishing system.

2. The electromagnetic system and the main contact arc extinguishing system are respectively fixed on the installation base frame, adopting a corner-turning beat-type electromagnetic system and a double-winding attraction coil to install a pressure ribbed device on the rotating edges and corners;

3. The contactor is made of copper. low resistance and fast response
remote control

1. Long-distance wireless control;

2. Reliable, stable, self-locking and interlocking function, strong anti-interference ability, long service life
Voltage acquisition

Measuring voltage: 0-100V, guarantee test accuracy

Display accuracy: F.S ±0.2% rdg ±1digit

Action method: 2 integral methods

Acquisition frequency: 2 times / second

Number of channels: 2 channels
Current acquisition

Measuring current: 0-1000A

Display accuracy: F.S ±0.2% rdg ±1digit

Action method: 2 integral methods

Acquisition frequency: 2 times / second

Number of channels: 2 channels
Temperature acquisition

Measuring temperature: -20-600°C

Display accuracy: 0.5°C

Acquisition frequency: 1 time/second

Number of channels: 4 channels
Equipment material

Inner box 1.5mm SUS#201 stainless steel,

Outer box: 1.5mm cold-rolled steel plate baking treatment
Ventilation function There is an air inlet on the left side of the equipment and a smoke outlet on the top. The exhaust gas produced during the test can be discharged to the outdoor through the top blower and reserved exhaust duct.
Explosion-proof function

1. The observation window is three layers of tempered glass.

2. Test box structure is divided into inner layer, outer layer, and intermediate sandwich.

3. The test box door is made of stainless steel high-strength hinge, safe and reliable.

4.Pressure relief device: there is a pressure relief and explosion-proof window at the back of the device, with a diameter of 100mm.
Test mode interface RT + 10~100℃ Battery External Short Circuit Test Chamber PLC / Remote Control upto 1000A ( UN38.3.4.5)
  RT + 10~100℃ Battery External Short Circuit Test Chamber PLC / Remote Control upto 1000A ( UN38.3.4.5)
  RT + 10~100℃ Battery External Short Circuit Test Chamber PLC / Remote Control upto 1000A ( UN38.3.4.5)
  RT + 10~100℃ Battery External Short Circuit Test Chamber PLC / Remote Control upto 1000A ( UN38.3.4.5)
  RT + 10~100℃ Battery External Short Circuit Test Chamber PLC / Remote Control upto 1000A ( UN38.3.4.5)

 

 


Configuration

Test machine: 1 Set


Standard side wiring: 2 Pairs


Remote controller : 1 Set


Standard asbestos board: 2 PCS

Contact Details
Dongguan City Gaoxin Testing Equipment Co., Ltd.

Contact Person: Johnny Jiang

Send your inquiry directly to us (0 / 3000)

Other Products