No.7, Shengfeng Road 523039, Xinhe Industrial Park, Wanjiang, Dongguan, Guangdong, China
Home ProductsIEC62133 Battery Testing Equipment

Battery External Short Circuit Test Chamber With Current, Voltage, Temperature Acquisition Channels

Battery External Short Circuit Test Chamber With Current, Voltage, Temperature Acquisition Channels

Battery External Short Circuit Test Chamber With Current, Voltage, Temperature Acquisition Channels

Product Details:

Place of Origin: China
Brand Name: Gaoxin
Certification: ISO 2008
Model Number: GX-6055-NT

Payment & Shipping Terms:

Minimum Order Quantity: 1set
Price: negotiation
Packaging Details: Non-fumigation wooden box
Delivery Time: 25 working days
Payment Terms: FOB Shenzhen, L/C, T/T, Western Union
Supply Ability: 50 sets per month
Contact Now
Detailed Product Description
Internal Resistance Of Device: 80±20mΩ Maximum Measurable Battery Voltage: 100V
Max. Circuit Current: 1000A Test Temperature Range: RT+10~100℃
Short Circuit Mode: Room Temperature/High Temperature Short Circuit / Short Circuit Protection Test Space: 400*400*400mm

Product name: Battery Short Circuit Test Machine


Model number: GX-6055-NT


Equipment description


The remote controlled high current short circuit test machine is designed to meet the various battery short-circuit test requirements. The short circuit test machine must meet the internal resistance range according to the standard requirements. ≤100mΩ to obtain the maximum short-circuit current required by the test.
Control mode: PLC control, use Schneider AC contactor as switch component, set test conditions on PLC interface, contactor suck and send strong short-circuit current to make the whole circuit short, reach the test required current, The loop resistance in the process of the equipment (ie contactor resistance + connection terminal + battery fixture total resistance of 80 ± 20mΩ). The maximum short-circuit current from the contactor is 1000A. The maximum short-circuit current that the test circuit can withstand is 1000A. The battery surface temperature, voltage change data, and current change data during the test are detected by the acquisition element and fed back to the PLC main control program.

 

Technical Parameter

 

Working voltage AC 220V 50Hz-60Hz
Impact voltage AC 1kv/1.2-50μs <peak value> 1min
Operation characteristics

Cold state pull-in voltage ≯66%Us

Cold state releasing voltage ≯30%Us,≮5%Us
Short circuit mode Pneumatic suction
Maximum measurable battery voltage 100V
HVDC response time ≤5μs
Max. circuit current 1000A
Internal resistance of device 80±20mΩ
Remote control distance 7 meter
Test temperature range RT+10~100℃
Current, voltage, temperature acquisition channels Total 8 channels
Actuation time Response time / releasing time ≯30ms
Mechanical life 300,000 times
Temperature control accuracy 0.1℃
Temperature uniformity ±2℃
Temperature fluctuation ±0.5℃
Interior test chamber size 400*400*400mm
External test chamber size 950*850*1650mm
Working environment Temperature: -10℃~100℃ humidity: 10~90%RH
Short Circuit Mode

Room temperature short circuit

High temperature short circuit

Short circuit protection
Supply power AC220V , 50HZ
Equipment power 2.5KW

 

Test mode interface Battery External Short Circuit Test Chamber With Current, Voltage, Temperature Acquisition Channels
  Battery External Short Circuit Test Chamber With Current, Voltage, Temperature Acquisition Channels
  Battery External Short Circuit Test Chamber With Current, Voltage, Temperature Acquisition Channels
  Battery External Short Circuit Test Chamber With Current, Voltage, Temperature Acquisition Channels
  Battery External Short Circuit Test Chamber With Current, Voltage, Temperature Acquisition Channels


 

Contact Details
Dongguan City Gaoxin Testing Equipment Co., Ltd.

Contact Person: Annie Chen

Send your inquiry directly to us (0 / 3000)

Other Products