High Low Temperature Battery External Short Circuit Tester With Data Acquisition
Product Details:
| Place of Origin: | China |
| Brand Name: | Gaoxin |
| Certification: | ISO 2008 |
| Model Number: | GX-6055-BHL |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1set |
|---|---|
| Price: | negotiation |
| Packaging Details: | Non-fumigation wooden box |
| Delivery Time: | 25 working days |
| Payment Terms: | FOB Shenzhen, L/C, T/T, Western Union |
| Supply Ability: | 50 sets per month |
|
Detail Information |
|||
| Internal Resistance Of Device: | 80±20mΩ | Maximum Measurable Battery Voltage: | 100V |
|---|---|---|---|
| Max. Circuit Current: | 1000A | Test Temperature Range: | -20~150℃ |
| Short Circuit Mode: | Room Temperature/High Low Temperature Short Circuit | Test Space: | 500*500*500mm |
| Data Acquisition: | 5 Channels Of Each | ||
| Highlight: | High Low Temperature Short Circuit Tester,Short Circuit Tester With Data Acquisition,High Low Temperature Battery |
||
Product Description
High - Low Temperature Battery External Short Circuit Test Machine With Data Acquisition
Product name: Battery Short Circuit Test Machine
Model number: GX-6055-BHL
Equipment description
The remote controlled high current short circuit test machine is designed to meet the various battery short-circuit test requirements. The short circuit test machine must meet the internal resistance range according to the standard requirements. ≤100mΩ to obtain the maximum short-circuit current required by the test.
Technical Parameter
| Working voltage | AC 220V 50Hz-60Hz |
| Impact voltage | AC 1kv/1.2-50μs <peak value> 1min |
| Operation characteristics |
Cold state pull-in voltage ≯66%Us Cold state releasing voltage ≯30%Us,≮5%Us |
| Short circuit mode | Pneumatic suction |
| Maximum measurable battery voltage | 100V |
| HVDC response time | ≤5μs |
| Max. circuit current | 1000A |
| Internal resistance of device | 80±20mΩ, ≤ 20mΩ |
| Remote control distance | 7 meter |
| Test temperature range | -20~150℃ |
| Current, voltage, temperature acquisition channels | 5 channels of each |
| Actuation time | Response time / releasing time ≯30ms |
| Mechanical life | 300,000 times |
| Temperature control accuracy | 0.1℃ |
| Temperature uniformity | ±2℃ |
| Temperature fluctuation | ±0.5℃ |
| Interior test chamber size | 400*400*400mm |
| External test chamber size | 950*850*1650mm |
| Working environment | Temperature: -10℃~100℃ humidity: 10~90%RH |
| Short Circuit Mode |
Room temperature short circuit High temperature short circuit Short circuit protection |
| Supply power | AC220V , 50HZ |
| Equipment power | 2.5KW |
![]()