Half Sine Acceleration Shock Test Systems Meets Battery Safety Testing UN 38.3 IEC62133
Product Details:
Place of Origin: | China |
Brand Name: | Gaoxin |
Certification: | ISO |
Model Number: | GX-5099-S |
Payment & Shipping Terms:
Minimum Order Quantity: | 1set |
---|---|
Price: | negotiation |
Packaging Details: | Non-fumigation wooden box |
Delivery Time: | 40 working days |
Payment Terms: | FOB Shenzhen,T/T, |
Supply Ability: | 50 sets per month |
Detail Information |
|||
Working Table: | 250*200mm | Max Load: | 10kg |
---|---|---|---|
Peak Acceleration: | 20—1500G | Pulse Duration: | 0.5-7ms |
Dimension: | 600×550×1950mm(L×W×H) | Electrical Requirements: | AC220V±10% 50Hz,1KVA & 0.5—0.7MPa |
High Light: | battery testing instruments,battery testing machine |
Product Description
Half Sine Shock Test Systems Meets Battery Testing UN 38.3 IEC62133
1. Product Name: Battery Acceleration Shock Tester
2. Product model: GX-5099-S
Feature:
-
Precise screw, motor and guide pillar to make sure the stable and exact lifting to get the accurate data.
-
The impact base is equipped with airbag and damper to protect the machine structure.
-
No resonance design to ensure the data precision.
-
Pneumatic friction brake to avoid the secondary impact.
-
Equipped with energy storage cylinder to ensure the stability of brake mechanism pressure.
-
Single-channel data acquisition. The tester can performs such functions like acceleration data measurement, storage, report forms printing, data correction, database management, etc.
-
Waveform generator:
Semi-sinusoidal waveform generator, semi-sine wave generator is mainly made of engineering rubber or wool felt. A variety of different thicknesses are connected in series to form a plurality of stiffnesses to achieve different impact pulse widths.
Analysis function: transient capture of shock waveform, shock response spectrum, Force deformation analysis, impact response demonstration, rotational shock analysis and other necessary analysis in impact test
Specifications:
Main parameters | |
Working table | 200*200mm |
Max load | 10kg |
Peak acceleration | 20—1500G |
Pulse duration | 0.5-7ms |
Dimension(L×W×H) | 600×550×1950mm |
Net weight | 650 kg |
Electrical requirements | AC220V±10% 50Hz,1KVA & 0.5—0.7MPa |
Measurement system | |
Input channel | 2 CH |
Sampling frequency | 192kHz |
Input form | Voltage, charge |
Coupling method | AC, DC, ICP |
Pulse duration | 50-1ms |
Voltage range | -10V~+10V |
Shock waveform | Half sine |
The operating system | Microsoft Win XP/Win7/Win 8 |
Interface | USB 2.0 |
Sensor of acceleration | |
Brand | B&W |
Model | 22100 |
Output mode | Charge type |
Sensitivity | 3.93 pc/g |
Frequency range | 0.5-12Khz |
Acceleration range | ±2500G |
Working environment | -40~+160℃ |
Reliability |
The average failure rate≥5000 hours Half-sine waveform generator for continuous use of not less than 8,000 times. |
For detail information please contact with us